General information about ADBC-125ID Intelligent AC Dummy Load:
Steady-state test: automatically detect 3-phase voltage, current, active power, inactivepower, apparent power, power factor, frequency, run time, total energy and so on Transient-state test: according the presetted power values, ADBC-125ID series can create a loading dips and drops, automatically detect the maximum and minimum values of each phase voltage, current and frequency in the dips and drops, and calculate the power &power factor in each phase.
Setting test: according the presetted values, ADBC-125ID series can increase the load in steps by proportion up to the maximum power, and then decrease the load in steps. In this process, ADBC-125ID series will automatically detect the maximum and minimum values of voltage, current and frequency, 3-phase power & power factor in each steps
Fluctuation test: according the presetted values, ADBC-125ID series can increase the load in steps by proportion up to the maximum power, and automatically detect the maximum and minimum values of voltage, current and frequency, 3-phase power & power factor
Harmonics analysis: ADBC-125ID series can analyze the current, voltage 2-20 THD (total harmonic distortion) in each phases
ADBC-125ID series can support both 3-phase and 1-phase power test. The most powerful unit can provide 100KW
Parallel operation: for the requirement of some high power test, ADBC-125ID series can co-work in parallel perfectly
Phase sequence test: automatically detect the phase sequence of the generator &UPS
Adopting 5.7 inch colorful touching LCD: English interface make the operation convenient and direct viewing Without PC and other recording device, the internal data storage memory of ADBC-125ID series can save 250 groups of data The user can choose browsing the real-time data in the process of testing by the software shown by laptop screen, or download the data to PC by RS-485 or USB after the testing Applying overheating precaution function, ADBC-125ID series can cut off the load, terminate the discharge and alarm the user automatically when overheating happen
ADBC-125ID series provide the emergent stop switch, the users can terminate the test manually by single button Short circuit protection function, guarantee the test safe and stable.
Technical specification of the device:
TYPE | 20KW | 50KW | 100KW | 200KW | 500KW |
Loading Power (Max) | 0~20KW | 0~50KW | 0~100KW | 0~200KW | 0~500KW |
Power Factor | Test Range: 0.001~1.000; / Resolution: 0.001;/ Accuracy: 0.5% | ||||
Harmonics (THD) | Test Range: 2~50 harmonics (THD); / Resolution: 0.01%; / Accuracy: 1% | ||||
Voltage | Test Range: AC 0~450V; / Resolution: 0.1V; /Accuracy: 0.5% | ||||
Frequency | Test Range: 45~65Hz; / Resolution: 0.01Hz;/ Accuracy: 0.2% | ||||
Current Display | Resolution: 0.1A; / Accuracy: 0.5% | ||||
Input Voltage | AC 3 Phase 380V/ AC 1 Phase 220V | ||||
Discharging Time | 0~99 hours 59 minutes, constant adjustable | ||||
Cooling Mode | Air Cooling | ||||
Communication | RS232, USB | ||||
Control Mode | Discharge power constant adjustable | ||||
Storage Device | built-in large-capacity memory, users also can download the test data to PC or U disk by the USB port | ||||
Dimension(mm) | 830×280×520 | 980×304×696 | 660×790×980 | 600×920×1710 | 1560x650x1800 |
Weight (kg) | 30 | 50 | 113 | 230 | 300 |